Telefon: +39 0422 362444    Email: info@microtecnicatrevisana.com
Specifiche tecniche degli accessori per radiatoriTechnical specifications and testsTechnische Spezifikationen von Zubehörteile für die Heizungsanlagenindustrie

Technische Spezifikationen von Zubehörteile für die Heizungsanlagenindustriei

Technische Spezifikationen und tests für Zubehörteile für die Heizungsanlagenindustriei

TECHNISCHE DATEN UND TESTVERFAHREN FĂśR DIE ZUBEHĂ–RTEILE FĂśR HEIZKĂ–RPER (in English


MT2000-2
Torsion's test for the body of the vent: Maximum torsion strength 75 Nm, to close we recommend 30 Nm.
Torsion's test on the screw: Maximum torsion strength 5 Nm, to close we recommend 1,2 Nm.
Seal's test: all the vents are automatically tested (6 bar), highest pressure applied in the test room (16 bar).

2201631*
Torsion's test for the stop: Maximum torsion strength 80 Nm, to close we recommend 35 Nm.
Seal's test: highest pressure applied in the test room (16 bar).

TAPPO1/2
Torsion's test for the stop: Maximum torsion strength 80 Nm, to close we recommend 35 Nm.
Seal's test: highest pressure applied in the test room (16 bar).

MT2000-3/8
Torsion's test for the body of the vent: Maximum torsion's strength 50 Nm, to close we recommend 22 Nm.
Torsion's test on the screw: Maximum torsion's strength 5 Nm, to close we recommend 1,2 Nm.
Seal's test: all the vents are automatically tested (8 bar), highest pressure applied in the test room (8 bar).

2201631-3/8
Torsion's test for the stop: Maximum torsion strength 70 Nm, to close we recommend 32 Nm.

MT200014
Torsion's test for the stop: Maximum torsion strength 35 Nm, to close we recommend 12 Nm.
Seal's test: highest pressure applied in the test room (8 bar).

TAPPO1/4
Torsion's test for the stop: Maximum torsion strength 35 Nm, to close we recommend 17 Nm.
Seal's test: highest pressure applied in the test room (8 bar).

MT200018
Torsion's test for the stop: Maximum torsion strength 30 Nm, to close we recommend 12 Nm.
Seal's test: highest pressure applied in the test room (8 bar).

MT52
Torsion's test for the stop: Maximum torsion strength 87 Nm, to close we recommend 40 Nm.
Seal's test: highest pressure applied in the test room (8 bar).

MT50
Torsion's test for the body of the vent: Maximum torsion's strength 88 Nm, to close we recommend 40 Nm.
Torsion's test on the screw: Maximum torsion's strength 5 Nm, to close we recommend 1,2 Nm.
Seal's test: all the vents are automatically tested (8 bar), highest pressure applied in the test room (8 bar).


With exception to particular specifications of the customer the thickness of the nickel - plating is 4 Micron.
With exception to particular specifications all the o-rings are in EPDM 70 Shore and They can be utilized with
temperature 110C°.
For a proper functioning of our products, we recommend not to let the heating system reach temperatures lower than 5°C.
All the products are recommended to be used with a maximum pressure of 8 bar.

^